jeudi 7 août 2014

Linked capacity plus not working

I am working on a LCP system. The system has 4 sites with one MTR3000 at each site. The three peer repeaters are working perfectly. No data will go to or come from the master repeater. I have checked and rechecked ip numbers, UDP forwarding but nothing is letting all 4 repeaters come up. I have switched cabled and routers. The problem is following the master. The lasted firmware is installed.



I am testing this on the bench. 4 routers with 10.0.0.x WAN addresses each going to a switch.

Master 192.168.1.101 UDP 50010

Peer 192.168.2.102 UDP 50020

Peer 192.168.3.103 UDP 50030

Peer 192.168.4.104 UDP 50040



All port forwarding it in place. If I connect RDAC to the switch and point it at the master, 10.0.0.1, it reports back information on all 4 repeaters. So in know there is some connectivity. I can ping each router (10.0.0.x) when plugged into the switch.



The master repeater will act as a stand alone and the three peers work great together.



Does anyone who has actually set one of these systems up have any thoughts?



Jim




Aucun commentaire: