I am working on a LCP system. The system has 4 sites with one MTR3000 at each site. The three peer repeaters are working perfectly. No data will go to or come from the master repeater. I have checked and rechecked ip numbers, UDP forwarding but nothing is letting all 4 repeaters come up. I have switched cabled and routers. The problem is following the master. The lasted firmware is installed.
I am testing this on the bench. 4 routers with 10.0.0.x WAN addresses each going to a switch.
Master 192.168.1.101 UDP 50010
Peer 192.168.2.102 UDP 50020
Peer 192.168.3.103 UDP 50030
Peer 192.168.4.104 UDP 50040
All port forwarding it in place. If I connect RDAC to the switch and point it at the master, 10.0.0.1, it reports back information on all 4 repeaters. So in know there is some connectivity. I can ping each router (10.0.0.x) when plugged into the switch.
The master repeater will act as a stand alone and the three peers work great together.
Does anyone who has actually set one of these systems up have any thoughts?
Jim
I am testing this on the bench. 4 routers with 10.0.0.x WAN addresses each going to a switch.
Master 192.168.1.101 UDP 50010
Peer 192.168.2.102 UDP 50020
Peer 192.168.3.103 UDP 50030
Peer 192.168.4.104 UDP 50040
All port forwarding it in place. If I connect RDAC to the switch and point it at the master, 10.0.0.1, it reports back information on all 4 repeaters. So in know there is some connectivity. I can ping each router (10.0.0.x) when plugged into the switch.
The master repeater will act as a stand alone and the three peers work great together.
Does anyone who has actually set one of these systems up have any thoughts?
Jim
Aucun commentaire:
Enregistrer un commentaire